INT10 OC Anemometer
Article-Nr.: 13 N 293 S21

Productdetails
Application | Wind turbines and cranes |
Measuring principle | Contact-free magnetic scanning system |
Measuring range | 0-50m/s |
Accuracy | ±0.5m/s |
Resolution | <0.1m/s |
Start-up speed | <0.4m/s (ϑu=20C) |
Connection | DC 24V |
Signal output | 0-573Hz, open collector (sink/source) |
Signal availability | Max. 2.5s (from voltage-free state) |
Connection type | Cable (12m), 6x0.5mm2,shielded PUR sheath insulation TPE wire insulation |
Permissible ambient temperature T_A | -40…+70°C |
Permitted ambient temperature | -40…+70C When heating is not connected: Snow and ice-free sensor is prerequisite. |
Permissible relative humidity | 0-100% RH |
Stability | For wind speed of 80m/s (max. 30min) |
Heating: Type | Autonomously controlled heating |
Heating: Connection | AC/DC 24V ±20%Max. 20VA SELV |
Mounting | Central mounting M27 |
Housing: Material | Aluminium |
Housing: Corrosion resistance | Anodised |
Cup anemometer: Material | Aluminium |
Cup anemometer: Corrosion resistance | Powder-coated |
Weight | Approx. 1.4kg |
Check base | EN 61000-6-2, EN 61000-6-3, EN 61010-1 |
Approval | UL file no. E240032 |