Productdetails

Application Compressors acc. IEC/EN 60335
Functions Motor temperature static, Short circuit
Supply voltage AC 24-240V
Permitted ambient temperature -30...+70°C
Temperature measuring circuits: Type 1-2 AMS sensors in series alternative 1-9 PTC sensors acc. to DIN 44081, DIN 44082 in series
Temperature measuring circuits: R_25, total <1.8kΩ
Temperature measuring circuits: R_trip, static 4.5kΩ ±20%
Temperature measuring circuits: R_reset 2.75kΩ ±20%
Temperature measuring circuits: Max. length connection line 30m
Short circuit monitoring system PTC Typically <30Ω
Reset delay: Motor temperature static 30min ±5min, 60min ±5min
Reset of reset delay Main reset >5s only possible if there is no error current
Relay: Connection Refer to wiring diagram Max. 2.5A C300
Relay: Mechanical service life Approx. 1 million switching cycles
Interface Diagnose port (DP)
Protection class acc. To EN 60529 IP00
Connection type 6.3mm flat plugs
Housing material PA glass-fibre-reinforced
Mounting Screw mounted
Dimensions Refer to dimensions in mm
Weight Approx. 200g
Check base IEC/EN 60335, IEC/EN 60730, UL 60730 EN 61000-6-2, EN 61000-6-3 EN 61010-1 Overvoltage category II Pollution level 2
Approval UL File no. E75899 cURus VDE certification no. 40022017