Productdetails

Supply voltage AC/DC 24-240V
Permitted ambient temperature -30…+70°C
Temperature measuring circuits: Type 1-9 PTC sensors acc. to DIN 44081, DIN 44082 in series
Temperature measuring circuits: R_25, total <1.8kΩ
Temperature measuring circuits: R_trip, static 11.4kΩ ±20%
Temperature measuring circuits: R_reset 2.95kΩ ±20%
Temperature measuring circuits: Max. length connection line 30m
Motor voltage 3 AC 20-100Hz 80-575V ±10%
Phase monitoring: Phase sequence Active about 1s after motor start for about 5 seconds, Lock-out shut-off
Phase monitoring: Phase failure Active about 1 second after the motor start until the motor stop. Automatic restart after 10s. 4 shut-off within 20min or 11 shut-offs within 24h leads to locked shut-off
Phase monitoring: Inactive 10s after motor stop
Resetting the lock Main reset >5s
Relay: Connection AC 240V 2,5A C300 100mV 0.5mA
Relay: Mechanical service life Approx. 1 million switching cycles
Protection class acc. To EN 60529 IP00
Connection type 6.3mm flat plugs and screw type terminal
Housing material PA66, glas-fibre-reinforced
Mounting Can be snapped onto 35mm standard rail as per EN 60715 or screw mounted
Dimensions 68.4x33x80 (LxWxH)
Weight Approx. 120g
Check base EN 61000-6-2 EN 61000-6-3 EN 61010-1
Approval UL File no. E75899 cURus