Productdetails

Application Compressors with individually led out PTC sensors
Functions Motor temperature static, Motor temperature dynamic, Supply voltage
Supply voltage AC 120/240V
Undervoltage limits 85V (120V mains) / 170V (240V mains)
Permitted ambient temperature -40...+70°C
Temperature measuring circuits: Type 3 separate inputs for PTC sensors acc. to DIN 44081, DIN 44082
Temperature measuring circuits: R_trip, static 13kΩ ±3kΩ
Temperature measuring circuits: R_reset 3.25kΩ ±0.5kΩ
Temperature measuring circuits: Max. length connection line 30m
Reset delay: Motor temperature static 2min ±20s
Reset of reset delay Activation of the reset input only possible if there is no error current
Relay: Connection Refer to wiring diagram Max. 2.5A C300
Relay: Mechanical service life Approx. 1 million switching cycles
Interface Diagnose port (DP)
Protection class acc. To EN 60529 IP00
Connection type 6.3mm flat plugs
Housing material PA glass-fibre-reinforced
Mounting Screw mounted
Dimensions Refer to dimensions in mm
Weight Approx. 200g
Check base EN 61000-6-2, EN 61000-6-3 EN 61010-1 Overvoltage category II Pollution level 2
Approval UL File No. E75899 cURus
Reset delay 2min ±20s