Optical phase sensor mounted directly on the sight glass

2026-11-04 News, Products, HVAC/R

INT700 a new Diagnostic and Protection Monitoring Solution in the Refrigeration Circuit

In RACHP (Refrigeration, Air Conditioning, and Heat Pump) systems, stable operating conditions within the refrigeration circuit are crucial for efficiency, availability, and component protection. Particularly critical are two-phase conditions occurring at locations where a single-phase state is expected: 
such as liquid refrigerant in the suction line or gas bubbles in the liquid line.

With the INT700, KRIWAN introduces an optical phase sensor that is mounted externally on a sight glass and detects phase changes within the refrigerant flow, without requiring the refrigeration circuit to be opened.

Why Is Phase Monitoring Critical During Operation?

In practice, many conditions within the refrigeration circuit are assessed using pressure and temperature measurements. These values can be used, for example, to calculate superheat and subcooling. What is often missing, however, is direct, location-specific information about whether the refrigerant at a particular measuring point is in a single-phase or two-phase state. Especially during dynamic load changes, start-stop operation, or as components age, operating conditions can arise that become visible in standard measurements only indirectly or with a delay. 

Typical examples: 

1. Liquid refrigerant in the suction line (low-pressure side) often indicates an operating condition that may be critical from a compressor protection perspective.

2. Gas bubbles in the liquid line (high-pressure side), particularly flash gas, are often an indication of insufficient subcooling, undercharging, or excessive pressure losses, all of which can negatively affect cooling capacity and system efficiency.

Continuous phase monitoring at the sight glass can therefore provide an additional layer of sensing. It is not intended to replace established measurement methods, but rather to complement them with valuable diagnostic and protection information for event detection and trend analysis.

Measurement Principle

Optical Sensor Mounted Externally on the Sight Glass

The INT700 detects phase changes using a reflection-based optical measuring principle and is mounted externally on the sight glass. This allows the refrigeration circuit to remain closed, which is a key requirement for avoiding interference with the refrigerant and reducing installation effort.

The INT700 utilizes optical reflections within the sight glass and the refrigerant itself. When a phase change occurs, the optical reflection changes significantly, typically resulting in a clear drop in the analog signal. If varying proportions of gas and liquid are present within the measurement area, this is indicated by fluctuations in the output signal.

 

Which Conditions Can Be Detected?

  1. Gas content in the liquid line (e.g., flash gas).
  2. Liquid content in the suction line. Depending on the operating conditions, this may involve refrigerant as well as oil. 

From a system perspective, the key advantage is that this information is generated locally at the sight glass. As a result, events can be detected that are not always clearly identifiable through calculated parameters alone, such as superheat and subcooling.

Use Case 1: 
Phase Monitoring in the Suction Line

On the low-pressure side, the presence of liquid in the suction line is often an indication of critical operating conditions. Such conditions should be taken seriously, both from a compressor protection perspective and for system optimization and energy-efficient operation.

Possible causes include insufficient superheat, reduced evaporator performance, transient conditions during compressor start-up, and increased oil carryover into the refrigeration circuit resulting from improperly functioning or inadequately maintained oil separation systems.

Potential consequences range from liquid slugging with possible compressor damage and insufficient lubrication caused by oil dilution to efficiency losses resulting from reduced heat transfer performance.

The INT700 signal enables reliable detection of critical conditions and provides not only event information but also signal trends for service and troubleshooting purposes. As a result, the sensor can help stabilize superheat and support operation closer to the optimum operating point, without tolerating safety-critical wet vapor conditions.

Use Case 2: 
Phase Monitoring in the Liquid Line

On the high-pressure side, maintaining a stable single-phase liquid state in the liquid line is often a key prerequisite for efficient and reliable system operation. The presence of a two-phase mixture, particularly flash gas, typically indicates insufficient subcooling, an undercharged system, or significant pressure losses within the line.

Possible causes include reduced condenser performance, increasing pressure losses, and refrigerant shortage.

Potential consequences range from reduced cooling capacity and associated efficiency losses to unstable operating conditions.

Monitoring for flash gas with the INT700 helps operators keep subcooling under control while enabling the early detection of undercharging conditions or refrigerant leaks. This allows maintenance activities to be planned based on actual system condition, before efficiency and overall system performance begin to deteriorate noticeably.

System Integration

Depending on the system design, phase monitoring data can be used for a variety of protection, diagnostic, and optimization functions.

To facilitate integration into existing control and monitoring systems, the INT700 provides two signal outputs:

In practice, this enables a two-level approach:

  1. Event-Oriented Monitoring: Detection and reporting of critical operating conditions (e.g., Liquid content in the suction line, Flash gas in the liquid line).
  2. Trend- and Condition-Based Monitoring: Evaluation of signal trends over time to support Service activities, Troubleshooting an Assessment of operational stability.

In addition, the USB-C interface, in combination with the KRIWAN Service App, provides access to measurement data and configuration settings. An integrated LED indicator supports quick assessment during commissioning and service operations.

Design Considerations: The appropriate threshold values, time filters, and evaluation logic depend heavily on the specific application, control strategy, and expected operating conditions. For example, start-stop systems and modulating systems may require different parameter settings.

Learn more about the KRIWAN Service App

Technical Data

In addition to the technical specifications listed in the table below, the INT700 is designed for vibration-resistant mounting and features a sealed housing that prevents the effects of icing, particularly in cold installation environments.

Supply voltage24V DC
Medium temperature (Tmedium)-40°C ≤ Tmedium ≤ +70°C
Analog output signalConfigurable z.B. 0-10V; 0-5V; 0,5-4,5V 
Digital output signalNPN; PNP transistor output
Max. 30V DC
ConnectionM8 Connector, 3-pin
USB-C
MountingSnap-on mounting + eyelets for additional cable ties

Applications 

Thanks to its installation on a sight glass and its ability to detect both gas- and liquid-dominated conditions, the INT700 offers a wide range of application possibilities. Typical examples include: 

  • Large refrigeration rack systems (e.g., in food retail and industrial applications)
  • Refrigerated display cases
  • Heat pumps
  • Special-purpose and laboratory systems

In addition, further applications are expected to emerge over time, particularly in areas where operators and service organizations are increasingly focusing on condition-based maintenance, remote diagnostics, and energy optimization.

Conclusion and Outlook

Optical phase monitoring at the sight glass provides an additional source of information for reliably detecting two-phase conditions, documenting events, and evaluating trends. As a result, the INT700 supports both compressor protection (e.g., in the presence of liquid in the suction line) and system efficiency (e.g., when flash gas occurs in the liquid line).

 

The start of series production is planned for Q2 2027. Detailed specifications regarding output variants, configuration options, and compatibility will be finalized and published as part of the product launch.

Learn more about the INT700

Do you have any questions or feedback about this blog post?