Image Enlarge image

Optical monitoring

INT278 LCA Level monitoring

  • Article No.

    52 S478 S60

  • Application

    Optical (contactless) level monitoring of many fluids for example, in the oil sump of motors, tanks, reservoirs, predominantly intended for the oil monitoring in motors.

  • Functional description

    The relay gets activated in 3 s after connecting the supply voltage. If a level is missing, the relay locks out and switches off after a 30 s delay on start up and a further delay time of 5 s. The electric part can be removed and can be replaced without opening the reservoir. The operating mode is displayed in a simple blink code using an LED.